MODEL: 650VA / 390W / 4socket

CMK Cash Price 2,000


INPUT Voltage: 140V - 290V

Frequency: (40-70) ± 1Hz

OUTPUT AVR Range: 220V ± 10% (Auto-sensing)

Capacity: 650VA / 390W

Frequency Range (Battery Mode) : (50/60) ± 1Hz (Frequency self-adapt system)

Transfer Time: ≤ 10ms

Waveform: Simulated Sine Wave

TEL/Modem Type (Optional) : RJ 45/11 surge protector

Communication Type (Optional) : Intelligent RS-232/USB

Interface

Protection Overload : 110% < load percentage ≤ 120%, buzzer beeps,

load percentage > 120%, output shuts off, buzzer beeps continuesly

Battery Type : Sealed Maintenance Free Lead Acid

Battery Number: 12V/7.5Ah x 1pcs

Recharge Time: 8 hours ≥ 90%

Back up Time : > 6Mins (Half Load)

Physical Net Weight :(Kgs) 4.1

Dimensions (mm): 280 x 101 x 14

MODEL: 1000VA / 600W / 4socket

CMK Cash Price  4,200


INPUT Voltage: 140V - 290V

Frequency: (40-70) ± 1Hz

OUTPUT AVR Range: 220V ± 10% (Auto-sensing)

Capacity: 1000VA / 600W

Frequency Range (Battery Mode) :(50/60) ± 1Hz (Frequency self-adapt system)

Transfer Time: ≤ 10ms

Waveform : Simulated Sine Wave

TEL/Modem Type (Optional) : RJ 45/11 surge protector

Communication Type (Optional) : Intelligent RS-232/USB

Protection Overload : 110% < load percentage ≤ 120%, buzzer beeps,

load percentage > 120%, output shuts off, buzzer beeps continuesly

Battery Type : Sealed Maintenance Free Lead Acid

Battery Number: 12V/7.5Ah x 2pcs

Recharge Time: 8 hours ≥ 90%

Recharge Time: > 6Mins (Half Load)

Physical Net Weight : 7.9

Dimensions (mm): 353 x 122 x 195

MODEL 2000VA / 1600W

CMK Cash Price 17,000


Voltage Range Low Line Transfer : 85VAC/75VAC/65VAC±5% or 160VAC/140VAC/120VAC/110VAC±5%

(Ambient Temp <35°C)(Based on load percentage 100%-80%/80%-70%/70%-60%/60%-0%)

Low Line Comeback: 95VAC/85VAC/65VAC or 175VAC/155VAC/135VAC/125VAC±5%

(Ambient Temp <35°C)(Based on load percentage 100%-80%/80%-70%/70%-60%/60%-0%)

High Line Transfer: 145VAC±5% or 300VAC±5%

High Line Comeback: 140VAC±5% or 290VAC±5%

Frequency Range: 40Hz ~ 70Hz

Phase: Single Phase with ground

Power Factor: ≥0.99 @ nominal voltage (input voltage)


Output Voltage: 100/110/115/120/127VAC or 200/208/220/230/240VAC

AC Voltage Regulation: ± 1% (Battery Mode)

Frequency Range: 47Hz ~ 53Hz or 57 ~ 63Hz (Syncronized Range)

Frequency Range Battery Mode: 50Hz ± 0.25Hz or 60Hz ± 0.3Hz

Overload: Ambient Temp <35°C

105% ~ 110%: UPS shuts down after 10mins at battery mode or transfer to bypass when utility is normal

110% ~ 130%: UPS shuts down after 1min at battery mode or transfer to bypass when utility is normal

>130% : UPS shuts down after 3secs at battery mode or transfer to bypass when utility is normal

Current Crest Ratio: 3:01

Harmonic Distortion: ≤ 3% THD (linear load); ≤ 6% THD (non-linear load)

Trasfer Time AC Mode to Battery Mode: Zero

Inverter to Bypass: 4 ms (typical)

Waveform Battery Mode: Pure Sinewave


AC Mode 89%

Battery Mode 87%


Standard Model Battery Type 12V / 9H

Numbers 4

Recharge Time 4 hours recover to 90% capacity (Typical)

Charging Current 1.0A (max)

Charging Voltage 54.7 VDC ± 1%

Long Run Model Battery Numbers 4/6/8/

Charging Current 1.0A/2.0A/4.0A/6.0A

Charging Voltage 54.7VDC-±1% / 82.1VDC-±1% / 109.4VDC-±1%


Standard Model Dimensions, DxWxH 397x145x220 (mm)

Long Run Model Net Weight (Kgs) 17


Smart RS-232 or USB Supports Windows 2000/2003/XP/Vista/2008/Windows 7/Windows 8/ Linux/ Unix and MAC

Optional SNMP Power management from SNMP manager and web browser

MODEL:3000VA / 2400W

CMK Cash Price 20,500


Voltage Range Low Line Transfer : 85VAC/75VAC/65VAC±5% or 160VAC/140VAC/120VAC/110VAC±5%

(Ambient Temp <35°C)(Based on load percentage 100%-80%/80%-70%/70%-60%/60%-0%)

Low Line Comeback: 95VAC/85VAC/65VAC or 175VAC/155VAC/135VAC/125VAC±5%

(Ambient Temp <35°C)(Based on load percentage 100%-80%/80%-70%/70%-60%/60%-0%)

High Line Transfer: 145VAC±5% or 300VAC±5%

High Line Comeback:140VAC±5% or 290VAC±5%

Frequency Range: 40Hz ~ 70Hz

Phase: Single Phase with ground

Power Factor: ≥0.99 @ nominal voltage (input voltage)


Output Voltage: 100/110/115/120/127VAC or 200/208/220/230/240VAC

AC Voltage Regulation : ± 1% (Battery Mode)

Frequency Range: 47Hz ~ 53Hz or 57 ~ 63Hz (Syncronized Range)

Frequency Range Battery Mode: 50Hz ± 0.25Hz or 60Hz ± 0.3Hz

Overload: Ambient Temp <35°C

105% ~ 110%: UPS shuts down after 10mins at battery mode or transfer to bypass when utility is normal

110% ~ 130%: UPS shuts down after 1min at battery mode or transfer to bypass when utility is normal

>130% : UPS shuts down after 3secs at battery mode or transfer to bypass when utility is normal

Current Crest Ratio: 3:01

Harmonic Distortion: ≤ 3% THD (linear load); ≤ 6% THD (non-linear load)

Trasfer Time AC Mode to Battery Mode: Zero

Inverter to Bypass: 4 ms (typical)

Waveform Battery Mode: Pure Sinewave


AC Mode 89%

Battery Mode 87%


Standard Model Battery Type 12V / 9H

Numbers 4

Recharge Time 4 hours recover to 90% capacity (Typical)

Charging Current 1.0A (max)

Charging Voltage 54.7 VDC ± 1%

Long Run Model Battery Numbers 4/6/8/

Charging Current 1.0A/2.0A/4.0A/6.0A

Charging Voltage 54.7VDC-±1% / 82.1VDC-±1% / 109.4VDC-±1%


Standard Model Dimensions, DxWxH 397x145x220 (mm)

Long Run Model Net Weight (Kgs) 17


Supports Windows 2000/2003/XP/Vista/2008/Windows 7/Windows 8/ Linux/ Unix and MAC